ULV 1000 19J and FL 1500 Technical Data Sheet: Precise Parameters and Tolerances

26 August 2026 47

Thesis: documentary analysis of the datasheet reveals key tolerances and parameters for evaluating luminaire compliance. Evidence: the datasheets specify electrical, metrological, and photometric parameters. Explanation: this allows for comparing ULV 1000 19 J FL=1500 in terms of luminous flux stability, power consumption, and control capabilities.

Context: selecting the datasheet as a data source provides a practical basis for design. Evidence: standard datasheet tables contain sections on radiated quantities and operating conditions. Explanation: engineers and designers rely on these sections when calculating mounting positions and heat dissipation.

1 — What the Datasheet Includes: General Structure and Regulatory Framework

Datasheet for ULV 1000 19J and FL 1500: Precise Parameters and Tolerances

Point: the datasheet systematizes parameters, tolerances, and mounting recommendations. Evidence: a typical datasheet contains a list of models, electrical parameters, measured photometric characteristics, and mounting recommendations. Explanation: this structure accelerates compliance verification against project requirements and power consumption calculations for retail spaces.

1.1 Mandatory Sections of the Datasheet

Point: the datasheet includes a list of sections and a data presentation format. Evidence: typically, the following blocks are present: electrical parameters, photometric characteristics, mechanical dimensions, and wiring diagrams. Explanation: the presence of these sections reduces the risk of errors during component selection and on-site installation.

1.2 Regulations and Standards Applicable to ULV 1000 19J and FL 1500

Point: regulations define measurement methodologies and tolerances. Evidence: references to GOST/TU/IEC in datasheets govern electrical safety, photometric measurements, and luminous flux degradation. Explanation: compliance with regulations facilitates documentary confirmation of quality and commissioning.

2 — Key Electrical Parameters: Comparison of ULV 1000 19J and FL 1500

Point: electrical parameters determine compatibility with the power grid and operating modes. Evidence: the datasheet specifies voltage, current, power, power factor, and operating temperature. Explanation: these data are crucial when calculating cable lines, fuses, and lighting control systems.

Parameter ULV 1000 19J FL 1500 Tolerance / Standard
Nominal Power 1000 W 1500 W ±5% (IEC 60598)
Operating Voltage 220–240 V AC 100–277 V AC Wide input frequency range
Power Factor (cosφ) ≥ 0.95 ≥ 0.97 At full load
Operating Current (at 230V) 4.35 A 6.52 A Maximum design current
IP Protection Class IP65 IP66 Dust and moisture protection

2.1 Nominal Power, Current, and Voltage

Point: nominal values affect the selection of protection equipment and transformers. Evidence: datasheets contain values for power (W), currents (A), and nominal voltage (V). Explanation: precise nominal values allow for the correct selection of circuit breakers and prevent power bus overloads.

2.2 Power Factors, Starting Characteristics, and Temperature Tolerances

Point: cosφ, inrush current, and thermal classes are critical for operational reliability. Evidence: the datasheet records cosφ, inrush current factors, and temperature ranges for bending and sealed zones. Explanation: this affects the selection of control gear and the calculation of the thermal regime of optics and heatsinks.

3 — Optical and Photometric Parameters: Lumens, Luminous Flux, and Distribution

Point: photometry determines the efficiency and cost-effectiveness of the solution. Evidence: datasheets provide values for luminous flux (lm), luminous efficacy (lm/W), CCT, and CRI. Explanation: these parameters allow for predicting illuminance, color rendering compliance, and energy costs for lighting.

INPUT (VCC) DRIVER LED+ LED- LED ARRAY

3.1 Luminous Flux, Luminous Efficacy, and Color Parameters

Point: it is important to know how much light the system produces at the power input. Evidence: the datasheet specifies nominal luminous flux, luminous efficacy, CCT (K) range, and CRI (Ra). Explanation: comparing ULV 1000 19J and FL 1500 using this data shows the difference in energy efficiency and light quality for retail areas.

3.2 Light Distribution Curves and Mounting Heights

Point: curve shapes and LDT/IES diagrams determine zoning. Evidence: the datasheet is equipped with distribution diagrams and data on 50% and 10% intensity angles. Explanation: this data is needed to calculate the number of luminaires, suspension height, and expected uniform illuminance level.

4 — How to Verify Parameters and Tolerances in the Datasheet: A Step-by-Step Guide

Point: verification must be systematic and documented. Evidence: a list of mandatory measurements is applied: voltage/current, luminous flux, case temperature, vibrations. Explanation: sequential verification according to the datasheet sections reduces the likelihood of returns and increases the service life of the installation.

4.1 Comparison of Datasheet Measurements: What and How to Measure

Point: it is important to cross-check datasheet values with independent measurements. Evidence: datasheets provide measurement methods, spectra, and test conditions. Explanation: comparing laboratory measurements with datasheet values reveals discrepancies that require adjustments to design tolerances.

4.2 Errors, Tolerances, and Acceptance Criteria

Point: acceptance criteria establish allowable deviations. Evidence: the datasheet contains allowable deviations for luminous flux and electrical parameters. Explanation: knowing these tolerances helps determine when a claim is required or when adjustment of the luminaire settings on-site is necessary.

5 — Typical Non-Conformances and Rapid Solutions

Point: discrepancies regarding luminous flux and thermal regimes are often found in datasheets. Evidence: typical issues include luminous flux degradation, elevated case temperatures, and driver instability. Explanation: rapid corrective measures include checking connections, replacing the driver, and adjusting the dimming mode.

5.1 Common Errors in ULV 1000 19J and FL 1500 Datasheets

Point: errors are associated with incorrect interpretation of test modes and conditions. Evidence: unsuitable test temperature conditions and incomplete degradation data are encountered. Explanation: correction requires clarifying the test methodology and performing additional photometry at operating temperatures.

5.2 Corrective Measures: From Adjustment to Component Replacement

Point: adjustments must be gradual and documented. Evidence: practical steps include checking the driver, adjusting current, and re-verifying luminous flux. Explanation: this minimizes downtime and provides a basis for claims if factory defects are detected.

6 — Recommendations for Manufacturers, Designers, and Service Engineers

Point: transparency of datasheet data increases trust and simplifies maintenance. Evidence: datasheet templates with sections on electrical, optical, mechanical, and control protocols are recommended. Explanation: a single format accelerates integration into BIM models and reduces the risk of errors during the installation phase.

6.1 Acceptance Checklist Template

Point: the checklist accelerates acceptance and diagnostics. Evidence: it includes criteria for electrical parameters, photometric quantities, and mechanical integrity. Explanation: using such a template ensures uniformity of acceptance across different sites and clear test history tracking.

6.2 Reporting and Documentation Standards for Acceptance

Point: reporting must include the datasheet version and measurement results. Evidence: measured values, wiring diagrams used, dates, and responsible persons are recorded in the report. Explanation: this facilitates subsequent degradation analysis and the resolution of disputed issues with the supplier.

Conclusion

  • Datasheet accuracy is critical for design: ULV 1000 19 J FL=1500 must be accompanied by a full set of electrical and photometric data to correctly assess operational risks.
  • Comparing parameters using datasheets allows for choosing optimal models in terms of energy efficiency and color rendering, reducing operating costs and returns.
  • It is recommended to use a single datasheet template and checklist during acceptance to standardize tests and accelerate commissioning.

Frequently Asked Questions

Is it possible to calculate the lifetime based on the ULV 1000 19J datasheet?

The datasheet specifies the expected luminous flux degradation and LED lifetime; this serves as a guideline for the designer. In practical evaluation, operating temperatures and the dimming mode must be considered, so it is better to confirm lifetime calculations with field measurements.

Which FL 1500 parameters are critical for retail spaces?

The main parameters are luminous flux, luminous efficacy, light distribution, and CRI. They affect showcase brightness and the overall atmosphere. Luminous flux stability during long-term operation and compliance with datasheet tolerances are also important.

What should be done in case of discrepancy between datasheet and actual measurements?

The first step is a documented verification using a template: measuring flux, checking power supply and temperature. If the discrepancy is confirmed, a claim is filed based on the measurement results, and the data is sent to the supplier for coordinated adjustment or replacement.

What are the allowable luminous flux tolerances under GOST for ULV 1000 and FL 1500?

According to industrial standards (including GOST R and IEC), the allowable deviation of the luminous flux from the nominal datasheet value is no more than ±10% during the initial operating period under nominal temperature conditions.